 DS1077 EconOscillator/Divider
www.maxim-ic.com
FEATURES
Processor-controlled or standalone solidstate oscillator Frequency changes on-the-fly Dual low-jitter, synchronous fixed frequency outputs 2-wire serial interface Frequency outputs 8.1kHz to 133MHz 0.5% variation over temp (+25C to +70C) 0.5% initial tolerance Nonvolatile (NV) frequency settings Single 5V supply No external components Power-down mode Synchronous output gating
PIN ASSIGNMENT
OUT1 OUT0 VDD VCC GND 1 2 3 4 8 7 6 5 SCL SDA CTRL1 CTRL0
150mil SO 118mil SOP Package
PIN DESCRIPTION
OUT1 OUT0 VCC GND CTRL1 CTRL0 SDA SCL
STANDARD FREQUENCY OPTION
Note: x denotes package option DS1077x-133 133.333MHz to DS1077x-125 125.000MHz to DS1077x-120 120.000MHz to DS1077x-100 100.000MHz to DS1077x-66 66.666MHz to 16.2kHz 15.2kHz 14.6kHz 12.2kHz 8.1kHz
- Main Oscillator Output - Reference Output - Power Supply Voltage - Ground - Control Pin for OUT1 - Control Pin for OUT0 - 2-Wire Serial Data Input/Output - 2-Wire Serial Clock
ORDERING INFORMATION
Note: XXX denotes frequency option DS1077Z-XXX 8-Pin 150mil SO DS1077U-XXX 8-Pin 118mil SOP
DESCRIPTION
The DS1077 is a dual-output, programmable, fixed-frequency oscillator requiring no external components for operation. The DS1077 can be used as a processor-controlled frequency synthesizer or as a standalone oscillator. The two synchronous output operating frequencies are user-adjustable in submultiples of the master frequency through the use of two on-chip programmable prescalers and a divider. The specific output frequencies chosen are stored in NV (EEPROM) memory. The DS1077 defaults to these values upon power-up. The DS1077 features a 2-wire serial interface that allows in-circuit on-the-fly programming of the programmable prescalers (P0 & P1) and divider (N) with the desired values being stored in NV (EEPROM) memory. Design changes can be accommodated in-circuit on-the-fly by simply programming different values into the device (or reprogramming previously programmed devices). Alternatively, for fixed frequency applications, previously programmed devices can be used and no connection to the serial interface is required. Pre-programmed devices can be ordered in customerrequested frequencies. The DS1077 is available in 8-pin SO or SOP packages, allowing the generation of a clock signal easily, economically, and using minimal board area. Chip-scale packaging is also available on request.
EconOscillator is a trademark of Dallas Semiconductor.
1 of 21
022703
DS1077
BLOCK DIAGRAM 1077 Figure1
SEL0 EN0 PDN0 Select DIV1 0M1 0M0 1M1 1M0 EN0 SEL0 PDN0 PDN1 CONTROL REGISTERS P1 PRESCALER (M DIVIDER) PROGRAMMABLE "N" DIVIDER OUT1 0M1 0M0 DIV1 P0 PRESCALER (M DIVIDER) MUX OUT0 MCLK Power-Down CONTROL LOGIC (TABLE 1) Enable
INTERNAL OSCILLATOR
CTRL0
2-WIRE INTERFACE 1M1 1M0
Power-Down
Enable CONTROL LOGIC (TABLE 2)
PDN1 SDA SCL
2 of 21
CTRL1
DS1077
OVERVIEW
A block diagram of the DS1077 is shown in Figure 1. The DS1077 consists of four major components: 1) Internal Master Oscillator, 2) Prescalers, 3) Programmable Divider, and 4) Control Registers. The internal oscillator is factory-trimmed to provide a master frequency (Master CLK) that can be routed directly to the outputs (OUT0 & OUT1) or through separate prescalers (P0 & P1). OUT1 can also be routed through an additional divider (N). The Prescaler (P0) divides the Master Clock by 1, 2, 4, or 8 to be routed directly to the OUT0 pin. The Prescaler (P1) divides the Master Clock by 1, 2, 4, or 8, which can be routed directly to the OUT1 pin or to the Divider (N) input, which is then routed to the OUT1 pin. The Programmable Divider (N) divides the Prescaler Output (P1) by any number selected between 2 and 1025 to provide the Main Output (OUT1) or it can be bypassed altogether by use of the DIV1 register bit. The value of N is stored in the DIV register. The Control Registers are user-programmable through a 2-wire serial interface to determine operating frequency (values of P0, P1, & N) and modes of operation. The register values are stored in EEPROM and therefore only need to be programmed to alter frequencies and operating modes.
PIN DESCRIPTIONS
Output 1 (OUT1)--This pin is the main oscillator output; its frequency is determined by the control register settings for the prescaler P1 (mode bits 1M1 & 1M0) and divider N (DIV word). Output 0 (OUT0)--A reference output, OUT0, is taken from the output of the reference select Mux. Its frequency is determined by the control register settings for CTRL0 and values of Prescaler P0 (mode bits 0M1 & 0M0) (see Table 1). Control Pin 0 (CTRL0)--A multifunctional input pin that can be selected as a MUX SELECT, OUTPUT ENABLE and/or a POWER-DOWN. Its function is determined by the user-programmable control register values EN0, SEL0, and PDN0 (see Table 1). Control Pin 1 (CTRL1)--A multifunctional input pin that can be selected as a OUTPUT ENABLE and/or a POWER-DOWN. Its function is determined by the user-programmable control register value of PDN1 (see Table 2). Serial Data Input/Output (SDA)--Input/Output pin for the 2-wire serial interface used for data transfer. Serial Clock Input (SCL)--Input pin for the 2-wire serial interface used to synchronize data movement on the serial interface.
3 of 21
DS1077
DEVICE MODE USING OUT0 Table 1
EN0 (BIT) 0 0 SEL0 (BIT) 0 1 PDN0 (BIT) 0 0 CTRL0 (PIN) 1 0 OUT0 (PIN) HI-Z HI-Z CTRL0 FUNCTION POWERDOWN* DEVICE MODE POWER-DOWN ACTIVE
1 MCLK/M MUX SELECT ACTIVE 0 MCLK 1 HI-Z OUTPUT 1 0 0 ACTIVE ENABLE 0 MCLK 1 HI-Z OUTPUT 1 1 0 ACTIVE** ENABLE 0 MCLK/M 1 HI-Z POWER-DOWN POWERX 0 1 DOWN 0 MCLK ACTIVE 1 HI-Z POWER-DOWN POWERX 1 1 DOWN 0 MCLK/M ACTIVE *This mode is for applications where OUT0 is not used, but CTRL0 is used as a device shutdown. **Default Condition
DEVICE MODE USING OUT1 Table 2
PDN1 (BIT) 0 0 1 1 CTRL1 (PIN) 0 1 0 1 CTRL1 FUNCTION OUTPUT ENABLE OUTPUT ENABLE POWER-DOWN POWER-DOWN OUT1 OUT CLK HI-Z OUT CLK HI-Z DEVICE MODE ACTIVE** ACTIVE** ACTIVE POWER-DOWN
**Default Condition NOTE: Both CTRL0 and CTRL1 can be configured as power-downs. They are internally "OR" connected so that either of the control pins can be used to provide a power-down function for the whole device, subject to appropriate settings of the PDN0 and PDN1 register bits (see Table 3).
4 of 21
DS1077
SHUTDOWN CONTROL WITH PDN0 AND PDN1 Table 3
PDN0 PDN1 SHUTDOWN CONTROL (BIT) (BIT) 0 0 NONE* 0 1 CTRL1 1 0 CTRL0 1 1 CTRL0 OR CTRL1 *CTRL0 performs a power-down if SEL0 and EN0 are both 0 (see Table 1).
REGISTER FUNCTIONS
The user programmable registers can be programmed by the user to determine the mode of operation (MUX), operating frequency (DIV), and bus settings (BUS). Details of how these registers are programmed can be found in a later section; in this section the functions of the registers are described. The register settings are nonvolatile, the values being stored automatically or as required in EEPROM when the registers are programmed via the SDA and SCL pins.
MUX WORD
MSB Name * PDN1 Default 0 0 setting PDN0 0 SEL0 1 EN0 1 0M1 0 0M0 0 LSB 1M1 0 MSB LSB 1M0 DIV1 - - - - - 0 0 xxx xxx second data byte
first data byte *This bit must be set to zero.
DIV1 (bit)
This bit allows the output of the Prescaler P1 to be routed directly to the OUT1 pin (DIV1 = 1). The N divider is bypassed so the programmed value of N is ignored. If DIV1 = 0 (default) the N divider functions normally.
0M1, 0M0, 1M1, 1M0 (bits)
These bits set the prescalers P0 and P1, to divide by 1, 2, 4, or 8 (see Table 4).
PRESCALER DIVISOR M SETTINGS Table 4
0M1 0 0 1 1 0M0 0 1 0 1 Prescaler P0 Divisor "M" 1** 2 4 8 1M1 0 0 1 1 1M0 0 1 0 1 Prescaler P1 Divisor "M" 1** 2 4 8
**Default Condition
5 of 21
DS1077
EN0 (bit)
(Default EN0 = 1)
1) If EN0 = 1 and PDN0 = 0 the CTRL0 pin functions as an Output Enable for OUT0, the frequency of the output being determined by the SEL0 bit. 2) If PDN0 = 1, the EN0 bit is ignored, CTRL0 will function as a power-down, and output OUT0 will always be enabled on power-up, its frequency being determined by the SEL0 bit. 3) If EN0 = 0 the function of CTRL0 is determined by the SEL0 and PDN0 bits (see Table 1).
SEL0
(Default SEL0 = 1)
1) If SEL0 = 1 and EN0 = PDN0 = 0, the CTRL0 pin determines the state of the MUX (i.e., the output frequency of OUT0). 2) If CTRL0 = 0 the output will be the Master clock frequency. 3) If CTRL0 = 1 the output will be the output frequency of the M prescaler. 4) If either EN0 or PDN0 = 1 then SEL0 determines the frequency of OUT0 when it is enabled. 5) If SEL0 = 0 the output will be the Master clock frequency. 6) If SEL0 = 1 the output will be the output frequency of the M prescaler (see Table 1).
PDN0
(Default PDN0 = 0)
1) This bit (if set to 1) causes CTRL0 to perform a power-down function, regardless of the setting of the other bits. 2) If PDN0 = 0 the function of CTRL0 is determined by the values of EN0 and SEL0. NOTE: When EN0 = SEL0 = PDN0 = 0, CTRL0 also functions as a power-down. This is a special case where all the OUT0 circuitry is disabled even when the device is powered up for power to saving when OUT0 is not used (see Table 1).
PDN1
1) If PDN1 = 1, CTRL1 will function as a power-down.
(Default PDN1 = 0)
2) If PDN1 = 0, CTRL1 functions as an output enable for OUT1 only (see Table 2.) NOTE (ON OUTPUT ENABLE AND POWER-DOWN): 1) Both enables are "smart" and wait for the output to be low before going to Hi-Z. 2) Power-down sequence first disables both outputs before powering down the device. 3) On power-up the outputs are disabled until the clock has stabilized (~8000 cycles). 4) In power-down mode, the device cannot be programmed. 5) A power-down command must persist for at least two cycles of the lowest output frequency plus 10ms.
6 of 21
DS1077
DIV WORD
MSB N9 N8 N7 N6 N5 N4 first data byte N3 LSB MSB N2 N1 N0 X X X X second data byte X LSB X
N
These ten bits determine the value of the programmable divider (N). The range of divisor values is from 2 to 1025, and is equal to the programmed value of N plus 2 (see Table 5).
PROGRAMMABLE DIVISOR N VALUES Table 5
BIT VALUE 0 000 000 000** 0 000 000 001 1 111 111 111 **Default Condition DIVISOR (N) 2 3 1025
BUS WORD
Name Factory Default 0* 0* 0* *These bits are reserved and must be set to zero. 0* WC 0 A2 0 A1 0 A0 0
A0, A1, A2
These are the device select bits that determine the address of the device.
(Default Setting = 000)
(Default Setting WC = 0) This bit determines when/if the EEPROM is written to after register contents have been changed. If WC = 0 the EEPROM is written automatically after a write register command. If WC = 1 the EEPROM is only written when the "WRITE " command is issued. Regardless of the value of the WC bit, the value of the BUS Register (A0, A1, A2) is always written immediately to the EEPROM.
WC
7 of 21
DS1077
2-WIRE SERIAL DATA BUS
The DS1077 supports a bidirectional 2-wire bus and data transmission protocol. A device that sends data onto the bus is defined as a transmitter, and a device receiving data as a receiver. The device that controls the message is called a "master." The devices that are controlled by the master are "slaves." The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates the START and STOP conditions. The DS1077 operates as a slave on the 2-wire bus. Connections to the bus are made via the open-drain I/O lines, SDA and SCL. A pull-up resistor (5kW) is connected to SDA. The following bus protocol has been defined (See Figure 2): Data transfer may be initiated only when the bus is not busy. During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in the data line while the clock line is high will be interpreted as control signals. Accordingly, the following bus conditions have been defined: Bus not busy: Both data and clock lines remain HIGH. Start data transfer: A change in the state of the data line from HIGH to LOW while the clock is HIGH defines a START condition. Stop data transfer: A change in the state of the data line from LOW to HIGH while the clock line is HIGH defines the STOP condition. Data valid: The state of the data line represents valid data when, after a START condition, the data line is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed during the LOW period of the clock signal. There is one clock pulse per bit of data. Each data transfer is initiated with a START condition and terminated with a STOP condition. The number of data bytes transferred between START and STOP conditions is not limited, and is determined by the master device. The information is transferred byte-wise and each receiver acknowledges with a ninth bit. Within the bus specifications a regular mode (100kHz clock rate) and a fast mode (400kHz clock rate) are defined. The DS1077 works in both modes. Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the byte has been received. The master device must generate an extra clock pulse, which is associated with this acknowledge bit. A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is stable LOW during the HIGH period of the acknowledge-related clock pulse. Of course, setup and hold times must be taken into account. When the DS1077 EEPROM is being written to, it will not be able to perform additional responses. In this case, the slave DS1077 will send a notacknowledge to any data transfer request made by the master. It will resume normal operation when the EEPROM operation is complete. A master must signal an end-of-data to the slave by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this case, the slave must leave the data line HIGH to enable the master to generate the STOP condition.
8 of 21
DS1077
DATA TRANSFER ON 2-WIRE SERIAL BUS Figure 2
SDA MSB slave address R/W direction bit acknowledgement signal from receiver
acknowledgement signal from receiver
SCL
1
2
6
7
8
9 ACK
1
2
3-8
8
9 ACK
START CONDITION
repeated if more bytes are transferred
STOP CONDITION OR REPEATED START CONDITION
Figure 2 details how data transfer is accomplished on the 2-wire bus. Depending upon the state of the R/ W bit, two types of data transfer are possible: 1) Data transfer from a master transmitter to a slave receiver. The first byte transmitted by the master is the slave address. Next, follows a number of data bytes. The slave returns an acknowledge bit after each received byte. 2) Data transfer from a slave transmitter to a master receiver. The first byte (the slave address) is transmitted by the master. The slave then returns an acknowledge bit. Next, follows a number of data bytes transmitted by the slave to the master. The master returns an acknowledge bit after all received bytes other than the last byte. At the end of the last received byte, a not acknowledge is returned. The master device generates all of the serial clock pulses and the START and STOP conditions. A transfer is ended with a STOP condition or with a repeated START condition. Since a repeated START condition is also the beginning of the next serial transfer, the bus will not be released. The DS1077 may operate in the following two modes: 1) Slave receiver mode: Serial data and clock are received through SDA and SCL. After each byte is received, an acknowledge bit is transmitted. START and STOP conditions are recognized as the beginning and end of a serial transfer. Address recognition is performed by hardware after the slave address and direction bit have been received. 2) Slave transmitter mode: The first byte is received and handled as in the slave receiver mode. However, in this mode, the direction bit will indicate that the transfer direction is reversed. Serial data is transmitted on SDA by the DS1077 while the serial clock is input on SCL. START and STOP conditions are recognized as the beginning and end of a serial transfer.
9 of 21
DS1077
SLAVE ADDRESS
A control byte is the first byte received following the START condition from the master device. The control byte consists of a 4-bit control code; for the DS1077, this is set as 1011 binary for read and write operations. The next three bits of the control byte are the device select bits (A2, A1, A0) and can be written to the EEPROM. They are used by the master device to select which of eight devices are to be accessed. The select bits are in effect the three least significant bits of the slave address. The last bit of the control byte (R/ W ) defines the operation to be performed. When set to a one a read operation is selected, and when set to a zero, a write operation is selected. Following the START condition, the DS1077 monitors the SDA bus, checking the device type identifier being transmitted. Upon receiving the 1011 code (changeable with one mask) and appropriate device select bits, the slave device outputs an acknowledge signal on the SDA line.
10 of 21
DS1077
2-WIRE SERIAL COMMUNICATION WITH DS1077 Figure 3
Send a "Standalone" Command SCL SDA
S 1 0 11 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A P
Start
Address Byte
DS1077 ACK
Command Byte
DS1077 Stop ACK
Write MSB of a Two-Byte Register SCL SDA
S 1 0 11 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A D7 D6 D5 D4 D3 D2 D1 D0 A P
Start
Address Byte
DS1077 ACK
Command Byte
DS1077 ACK
MSByte
DS1077 Stop ACK
Write to a Two-Byte Register SCL SDA
S 1 0 11 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A P
Start
Address Byte
DS1077 ACK
Command Byte
DS1077 ACK
MSByte
DS1077 ACK
LSByte
DS1077 Stop ACK
Write a Single Byte to an Addressed Register SCL SDA
S 1 0 11 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A A7 A6 A5 A4 A3 A2 A1 A0 A D7 D6 D5 D4 D3 D2 D1 D0 A P
Start
Control Byte
DS1077 ACK
Command Byte
DS1077 ACK
Byte Address
DS1077 ACK
Data Byte
DS1077 Stop ACK
Write Multiple Bytes to an Addressed Register SCL SDA
S 1 0 11 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A A7 A6 A5 A4 A3 A2 A1 A0 A D7 D6 D5 D4 D3 D2 D1 D0 A
Start
Control Byte
DS1077 ACK
Command Byte
DS1077 ACK
Starting Byte Address
DS1077 ACK
Byte n
DS1077 ACK
SCL SDA
D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 D3 D2 D1 D0 A P
Byte (n+1)
DS1077 ACK
Byte N
DS1077 Stop ACK
11 of 21
DS1077
2-WIRE SERIAL COMMUNICATION WITH DS1077 Figure 3 (continued)
Read Single Byte Register or MSB from a Two-Byte Register SCL SDA
S 1 0 1 1 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A R1 0 1 1 A2 A1 A0 Rd A D7 D6 D5 D4 D3 D2 D1 D0 N P
Start
Control Byte
DS1077 ACK
Command Byte
DS1077 Repeated Control Byte ACK Start
DS1077 ACK
MSByte
Master Stop NACK
Read from a Two-Byte Register SCL SDA
S 1 0 1 1 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A R1 0 1 1 A2 A1 A0 Rd A D7 D6 D5 D4 D3 D2 D1 D0 A
Start
Control Byte
DS1077 ACK
Command Byte
DS1077 Repeated Control Byte ACK Start
DS1077 ACK
MSByte
Master ACK
SCL SDA
D7 D6 D5 D4 D3 D2 D1 D0 N P
LSByte
Master Stop NACK
Read Multiple Bytes from an Addressed Register SCL SDA
S 1 0 1 1 A2 A1 A0 W A C7 C6 C5 C4 C3 C2 C1 C0 A A7 A6 A5 A4 A3 A2 A1 A0 A R1 0 1 1 A2 A1 A0 Rd A
Start SCL SDA
Control Byte
DS1077 ACK
Command Byte
DS1077 ACK
Starting Byte Address DS1077 Repeated Control Byte ACK Start
DS1077 ACK
D7 D6 D5 D4 D3 D2 D1 D0
A D7 D6 D5 D4 D3 D2 D1 D0
A
D7 D6 D5 D4 D3 D2 D1 D0
N
P
Byte n
Master ACK
Byte (n+1)
Master ACK
Byte N
Master Stop NACK
12 of 21
DS1077
COMMAND SET
Data and control information is read from and written to the DS1077 in the format shown in Figure 3. To write to the DS1077, the master will issue the slave address of the DS1077 and the R/ W bit will be set to 0. After receiving an acknowledge, the bus master provides a command protocol. After receiving this protocol, the DS1077 will issue an acknowledge, and then the master may send data to the DS1077. If the DS1077 is to be read, the master must send the command protocol as before, and then issue a repeat START condition and then the control byte again, this time with the R/W bit set to 1 to allow reading of the data from the DS1077. The command set for the DS1077 is as follows:
Access DIV [01]
If R/ W is 0, this command writes to the DIV register. After issuing this command, the next data byte value is to be written into the DIV register. If R/ W is 1, the next data byte read is the value stored in the DIV register.
Access MUX [02]
If R/ W is 0, this command writes to the MUX register. After issuing this command, the next data byte value is to be written into the MUX register. If R/ W is 1, the next data byte read is the value stored in the MUX register.
Access BUS [0D]
If R/ W is 0, this command writes to the BUS register. After issuing this command, the next data byte value is to be written into the BUS register. If R/ W is 1, the next data byte read is the value stored in the BUS register.
Write E2 [3F]
If WC = 0 the EEPROM is automatically written to at the end of each command. This is a DEFAULT condition. In this case the command WRITE E2 is not needed. If WC = 1, the EEPROM is only written when the WRITE E2 command is issued. On receipt of the WRITE E2 command the contents of the DIV and MUX registers are written into the EEPROM, thus locking in the register settings. EXCEPTION: The bus register is always automatically written to EEPROM after a write, regardless of the value of WC.
APPLICATION INFORMATION Power-Supply Decoupling
To achieve best results, decouple the power supply with 0.01F and 0.1F high-quality, ceramic, surfacemount capacitors as close as possible to VCC/GND of the device. Surface-mount components minimize lead inductance, which improves performance, and ceramic capacitors tend to have adequate high-frequency response for decoupling applications.
Current Consumption
The active supply current can be significantly reduced by disabling OUT0 when not required and setting its prescaler to divide by 8. Likewise, bypassing OUT1's divider (and using only the prescaler) also significantly reduces the supply current.
13 of 21
DS1077
ABSOLUTE MAXIMUM RATINGS
Voltage on Any Pin Relative to Ground Operating Temperature Range Programming Temperature Range Storage Temperature Range Soldering Temperature -0.5V to 6.0V -40C to +85C 0C to +70C -55C to +125C See IPC/JEDEC J-STD-020A Specification
DC ELECTRICAL CHARACTERISTICS
PARAMETER Supply Voltage High-Level Output Voltage (OUT1,OUT0) Low-Level Output Voltage (OUT1,OUT0) High-Level Input Voltage (CTRL1, CTRL0) High-Level Input Voltage (SDA, SCL) Low-Level Input Voltage (CTRL1, CTRL0) Low-Level Input Voltage (SDA, SCL) High-Level Input Current (CTRL1, CTRL0, SDA, SCL) Low-Level Input Current (CTRL1, CTRL0, SDA, SCL) Supply Current (Active) Standby Current (Power-Down) SYMBOL VCC VOH VOL VIH VIH VIL VIL IIH VIH = VCC = 5.25V IIL VCC = 5.25V, VIL= 0 ICC ICCQ CL = 15pF (Both Outputs) (-40C to +85C) Power-Down Mode IOH = -4mA, VCC = min IOL = 4mA CONDITION
(TA = -40C to +85C, VCC = 5V 5%)
MIN 4.75 2.4 0.4 2.1 0.7Vcc -0.3V -0.3V
VCC+ 0.3V VCC+ 0.3V
TYP 5
MAX 5.25
UNITS V V V V V V
NOTES 1
0.8 0.3Vcc
1
A
-1
A
50 2 5
mA A
10
14 of 21
DS1077
AC ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL CONDITION VCC = 5V, 25C Output Frequency Tolerance Over Temperature VCC = 5V, 70C fO
(TA = -40C to +85C; VCC = 5V 5%)
MIN -0.5 -0.5 TYP 0 0 MAX +0.5 +0.5 +2.7 +1.4 -0.7 % +0.7 +1.0 +1.25 % kHz MHz ms ms ms ms ms pF % 2 5 3 3 3 3 4 % 11 UNITS NOTES
Output Frequency Tolerance Over Voltage
fO
Combined Freq. Variation Output Frequency Min Output Frequency Max Power-Up Time Enable OUT1 from PDN Enable OUT0 from PDN OUT1 Hi-Z from PDN OUT0 Hi-Z from PDN Load Capacitance Output Duty Cycle (OUT1, OUT0) Output Jitter
fO fOUT tPOR + tSTAB tSTAB tSTAB tHiZ tHiZ CL
VCC = 5V, -3.3 -40C to +25C VCC = 5V, -1.4 +25C to +85C VCC = 4.75V, -1.0 25C VCC = 5.25V, 25C Over Temp (0C to +70C) -1.65 & Voltage 8.13
133 0.1 0.1 0.1 1 1 1 1 1 15 40 fOUT=133MHz M=1; DIV1=1 CL=12pF 3 sigma pk-topk 30 50 60
psec
15 of 21
DS1077
AC ELECTRICAL CHARACTERISTICS: 2-WIRE INTERFACE (-40C to +85C; VCC= 5V5%)
PARAMETER SCL Clock Frequency Bus Free Time Between a STOP and START Condition Hold Time (Repeated) START Condition LOW Period of SCL HIGH Period of SCL Set-Up Time for a Repeated START Data Hold Time Data Set-Up Time Rise Time of Both SDA and SCL Signals Fall Time of Both SDA and SCL Signals Set-Up Time For STOP Capacitive Load for Each Bus Line Input Capacitance SYMBOL fSCL tBUF tHD:STA tLOW tHIGH tSU:STA tHD:DAT tSU:DAT tR tF tSU:STO CB CI 5 CONDITION Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode Fast Mode Standard Mode MIN TYP MAX 400 100 1.3 4.7 0.6 4.0 1.3 4.7 0.6 4.0 0.6 4.7 0 0 100 250
20 + 0.1CB 20 + 0.1CB
UNITS kHz s s s s s
NOTES
6
0.9
s ns
7,8
300 1000 300
ns ns s
9 9
0.6 4.0 400
pF pF
9
NONVOLATILE MEMORY CHARACTERISTICS
PARAMETER Writes SYMBOL CONDITION +85C MIN 10,000 TYP MAX UNITS NOTES
NOTES:
1) 2) 3) 4) 5) 6) All voltages are referenced to ground. 8.13kHz is obtained from a -66MHz standard part. PDN is a power-down signal applied to either CTRL0 or CTRL1 pins as appropriate. Output voltage swings may be impaired at high frequencies combined with high output loading. After this period, the first clock pulse is generated. A device must internally provide a hold time of at least 300ns for the SDA signal (referred to the VIH MIN of the SCL signal) in order to bridge the undefined region of the falling edge of SCL. 7) The maximum tHD:DAT has only to be met if the device does not stretch the LOW period (tLOW) of the SCL signal.
16 of 21
DS1077
8) A fast mode device can be used in a standard mode system, but the requirement tSU:DAT>250ns must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line tR MAX + tSU:DAT = 1000ns + 250ns = 1250ns before the SCL line is released. 9) CB is the total capacitance of one bus line in pF. 10) OUT0 and OUT1 are operating at oscillator master frequency without divider. 11) Typical frequency shift due to aging is 0.5%. Aging stressing includes Level 3 preconditioning with 1000 temperature cycles of -55C to +125C, 336hr max VCC biased +125C bake. Level 3 preconditioning consists of a 24hr +125C storage bake, 192hr moisture soak at +30C/60% R.H., and three solder reflow passes.
TIMING DIAGRAM
SDA
tBUF tHD:STA tF
tLOW
tR
t SP
SCL t HD:STA STOP START t HD:DAT t SU:STO
tHIGH
t SU:DAT
t SU:STA REPEATED START
ORDERING INFORMATION
DS1077 133 = 125 = 120 = 100 = 66 = Example: DS1077Z-100 Z= U= SO SOP 133.333MHz 125.000MHz 120.000MHz 100.000MHz 66.666MHz
17 of 21
DS1077
TYPICAL OPERATING CHARACTERISTICS (VCC = 5.0V, T = +25C, unless otherwise specified)
SUPPLY CURRENT vs. VOLTAGE
45.00 40.00 35.00
CURRENT (mA)
30.00 25.00 20.00 15.00 10.00 5.00 0.00 4.5 4.7 4.9 5.1 5.3 5.5 VOLTAGE (V) DS1077-133 DS1077-100 DS1077-66
SUPPLY CURRENT vs. DIVISOR (N) DS1077-133
34 32 30
CURRENT (mA)
28 26 24 22 20 0 200 400 600 DIVISOR (N)
18 of 21
4.75V 5.0V 5.25V 800 1000
DS1077
TYPICAL OPERATING CHARACTERISTICS (continued) (VCC = 5.0V, T = +25C, unless otherwise specified)
SUPPLY CURRENT vs. DIVISOR (N)
35 30 25
CURRENT (mA)
20 15 10 5 0 0 200 400 600 800 1000 DIVISOR (N) DS1077-133 DS1077-100 DS1077-66
SUPPLY CURRENT vs. TEMPERATURE
45
40
CURRENT (mA)
35
30 DS1077-133 DS1077-100 25 DS1077-66
20 0 10 20 30 40 50 60 70
TEMPERAT URE (C)
19 of 21
DS1077
TYPICAL OPERATING CHARACTERISTICS (continued) (VCC = 5.0V, T = +25C, unless otherwise specified)
TEMPCO
2 1.5 1
% Change from 25C
0.5 0 -0.5 -1 -1.5 -2 0 10 20 30 40 50 60 70
TEMPERAT URE (C)
DS1077-133 DS1077-100 MUX=3040h DIV=0000h DS1077-66
VOLTCO
2.00 1.50
% CHANGE FROM 5V
1.00 0.50 0.00 -0.50 -1.00 -1.50 -2.00 4.75 4.85 4.95 5.05 5.15 5.25 VOLTAGE (V) MUX=3040h DIV=0000h DS1077-133 DS1077-100 DS1077-66
20 of 21
DS1077
TYPICAL OPERATING CHARACTERISTICS (continued) (VCC = 5.0V, T = +25C, unless otherwise specified)
SHUTDOWN CURRENT vs. TEMPERATURE
4 3.5 3
CURRENT (A)
2.5 2 1.5 DS1077-66 1 0.5 0 0 10 20 30 40 50 60 70
T EMPERAT URE (C)
21 of 21


▲Up To Search▲   

 
Price & Availability of DS1077U-125

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X